Electrical work in business premises falls under the Electricity at Work Regulations 1989 rather than the rules used for homes. As a business owner or commercial landlord, you have a legal duty to keep your electrical systems maintained to prevent danger. Periodic inspection, known as fixed wire testing, is the usual way to show you have done this.

Commercial electricians handle electrical systems in shops, offices, cafes, salons, industrial units and warehouses. Their work often differs from domestic wiring. Larger business premises may use three-phase electricity to run heavy machinery, large heating systems and commercial kitchens, and wiring is often run in metal conduit or cable trays rather than buried in plaster walls.

The rules governing the work are also different. The Planning Portal states that the building regulations set standards for electrical installation work only in relation to dwellings. If the work is carried out in industrial or commercial buildings, it is covered by workplace health and safety law. The Health and Safety Executive is responsible for making sure electrical installation work in these buildings is safe.

As a business owner, employer or commercial landlord, you have clear duties under health and safety law. The Electricity at Work Regulations 1989 apply to all work environments across Great Britain. Regulation 4 requires that all systems shall at all times be of such construction as to prevent, so far as is reasonably practicable, danger.

The regulation also states that, as may be necessary to prevent danger, all systems must be maintained so as to prevent that danger, so far as is reasonably practicable. Finally, every work activity, including the operation, use and maintenance of a system, must be carried out so that it does not give rise to danger, so far as is reasonably practicable.

There is no rule for commercial property like the fixed inspection intervals set for rented homes. The duty is to maintain your installation so as to prevent danger, and periodic inspection and testing recorded on an EICR is the usual way to show you are doing this.

Understanding commercial fit outs and repairs

When you open a new premises or refurbish an old one, the electrical work happens in two stages. First fix involves putting the hidden wiring, back boxes and containment systems in place. Second fix happens after the walls and ceilings are finished. This is when the electrician fits the consumer unit, sockets, light switches and light fittings.

A commercial consumer unit is often called a distribution board. It contains the main switch and safety devices like circuit breakers, an RCD or individual RCBOs for each circuit. An RCD is a device that switches the power off very quickly if it detects current leaking to earth, which reduces the risk of a fatal electric shock, while an RCBO combines this protection with an overload breaker for a single circuit. A surge protection device is also common in commercial boards to protect expensive computers and machinery from power spikes.

Proper earthing and bonding are critical parts of any commercial installation. Earthing provides a path for fault current so the protective device can switch the circuit off, while bonding connects metal pipes and other metalwork to the main earthing terminal so that the voltage between metal parts stays low if there is a fault. For general repairs, an electrician will trace the problem and replace damaged parts. They will issue an Electrical Installation Certificate for new circuits or a Minor Works Certificate for small additions and alterations to an existing circuit.

Fixed wire testing and the commercial EICR

Fixed wire testing is the trade term for the inspection and testing of the permanent electrical installation in a building. The electrician tests the wiring, the consumer unit, the sockets and the lighting circuits. They are checking for wear and tear, damage, and poor previous work that does not meet BS 7671, the national wiring standard.

The process involves a visual inspection followed by dead testing with the power off, and then live testing with the power on. The electrician will check that the earthing and bonding are intact and that RCDs trip within the correct time. As a business owner, the only test you should do yourself on the fixed wiring is pressing the RCD test button on your consumer unit periodically to check it trips.

The results are documented on a commercial electrical installation condition report, known as an EICR. This report will list any defects found and grade them by severity. You can learn more about the specific fault codes in the guide explaining what an EICR certificate is and who needs one.

How often business premises should be tested

The law does not specify exactly how often you must test your wiring. The Health and Safety Executive states that electrical installations should be tested often enough that there is little chance of deterioration leading to danger.

Electrical Safety First recommends that periodic inspection and testing is carried out at least every five years for a business. The interval depends heavily on the type of premises you run and the environment the wiring sits in.

Commonly used recommended intervals are every five years for offices and shops, every three years for industrial premises and every one to three years for entertainment venues. These are recommendations rather than legal deadlines. The testing electrician will assess the condition of your wiring and set the date for the next inspection on the report.

What a commercial EICR costs

Testing costs depend on the size of your building, the number of circuits and how easy it is to access the wiring. Some electricians price this work per circuit, plus a site visit fee.

This table shows common pricing structures for a commercial EICR.

Type of charge

Typical price

Small to medium unit (10 to 30 circuits)

£200 to £600

Per circuit price

£12 to £18

Site visit fee (added to per circuit price)

£60 to £80

These are typical published prices for 2026 in the Midlands and the North, and local quotes will differ.

Prices in London and the South East typically run 15 to 25% higher. These prices cover the inspection and the written report. Remedial work to fix any faults found during the test is quoted separately.

Typical hourly and daily rates

Small jobs, fault finding and minor repairs are usually charged by the hour or by the day. Defined jobs like a full shop fit out or installing a new commercial distribution board will be quoted as a fixed price.

This table shows typical general rates for electricians, which give a guide for repairs and other work charged by time.

Time on site

Outside London

London and South East

Hourly rate

£40 to £60

£55 to £75

Half day

£120 to £220

£180 to £280

Full day

£220 to £400

£300 to £450

Call-out fee

£60 to £120

£90 to £150

Emergency call-out

£120 to £350

£180 to £400

These are typical published prices for 2026 including VAT, and local quotes will differ.

A half day is roughly three to four hours and a full day is seven to eight hours. A standard call-out fee normally includes the first hour of work. Out-of-hours work carries a significant premium. London and the South East run roughly 15 to 30% higher than the North of England, Wales and Scotland.

Working around your opening hours

A thorough fixed wire test requires the electrician to turn off the power to parts of your building. Depending on which circuits are being tested, computers, tills, lighting, machinery and refrigeration can lose power while the work is done.

Because this disrupts normal trading, testing outside opening hours is common. Electricians frequently complete commercial testing in the evening, overnight, or on a Sunday.

You will pay more for out-of-hours work. When you ask for a quote, be clear about your trading hours so the electrician can price the job accurately. If you run servers or vital refrigeration, tell the electrician in advance so they can test those specific circuits quickly and restore power.

Checking competence and registration

The best way to find out if an installation is safe is to have it inspected and tested by a person with the competence to do so. The Health and Safety Executive explains that a person can show competence by completing an assessed training course run by an accredited training organisation. A completed electrical apprenticeship with some post-apprenticeship experience is also a good way of showing competence for general electrical work.

Look for an approved contractor from a body such as the ECA, NAPIT, NICEIC or SELECT. Check their membership directly with the body rather than trusting a logo on a van or a website.

You should also ask to see proof of their public liability insurance, and of employers' liability insurance if they employ staff, before work starts.

Common problems when hiring

Business owners often face the same common problems when hiring electrical contractors. Being aware of these traps will help you choose a reliable firm.

  • Very cheap inspections used to sell long lists of remedial work.
  • Advisory items presented as failures rather than recommendations.
  • Work handed over with no certificate or test results.
  • Vague quotes that leave out VAT or the cost of making good damaged plaster and decoration.
  • Emergency call-outs with no clear price given before the electrician arrives.
  • Contractors demanding large cash deposits upfront with no written paperwork.
  • Choosing a contractor on price alone, which can lead to rushed work and poor safety standards.

Emergency lighting, fire safety and portable appliances

Electrical safety ties heavily into fire safety. The responsible person for fire safety in a business or other non-domestic premises must carry out a fire risk assessment, put in place appropriate fire safety measures and plan for an emergency.

The responsible person could be the employer, owner, landlord, occupier or anyone else with control of the premises. For common or shared areas, the responsible person is usually the landlord, freeholder or managing agent. Scotland and Northern Ireland have different fire safety rules. You can find out more in the guide covering emergency lighting rules and testing.

Portable appliances are separate from fixed wiring. The Electricity at Work Regulations require electrical equipment that could cause injury to be maintained in a safe condition. The law does not specify what needs to be done, by whom or how often. This means PAT testing or annual testing is not a legal requirement in itself, although for equipment that is used a lot and moved around, testing alongside visual checks can be an important part of keeping it safe. The frequency depends on the type of equipment and the environment. You can read more about this in the guide explaining what PAT testing is.

What a good quote should include

A quote is a fixed price. An estimate is not. You should always ask for a detailed, written quote before agreeing to any commercial electrical work.

  • The scope of the work and the exact number of circuits included in the price.
  • Whether the final report and electrical certificates are included.
  • Any out-of-hours rates or premium charges for evening or weekend work.
  • How any remedial work will be priced if faults are found during an inspection.
  • Clear timescales for completing the work and delivering the paperwork.
  • Whether VAT and materials are included in the final figure.
  • Who is responsible for making good any plasterwork or decoration damaged during the job.

Questions to ask before you hire

Asking a few direct questions will help you separate experienced commercial contractors from domestic electricians who are out of their depth.

  • Are you an approved contractor registered with a body like NICEIC, NAPIT, ECA or SELECT?
  • Do you have experience working on three-phase commercial systems?
  • Will you need to turn the power off and for how long?
  • Can you complete the testing outside our normal trading hours?
  • Do you charge a minimum call-out fee or a site visit fee?
  • How long will it take to receive the commercial EICR paperwork after the test?

Common questions

What is the difference between an EICR and fixed wire testing?

Fixed wire testing is the physical process of inspecting and testing the electrical installation. A commercial EICR is the formal document produced at the end of that process. They refer to exactly the same safety check.

What happens if my business fails a fixed wire test?

The report will list what needs attention and how urgently. The electrician can quote for the remedial work, and once the repairs are done you should receive a certificate for that work. HSE also says any part of an installation that becomes obviously defective between tests should be switched off until the fault is fixed.

Can I test my own sockets to save money?

No. Plug-in socket testers cannot detect certain faults and could show a socket as safe when it is not. If you think an installation is unsafe, warn everyone to stay away, switch it off if it is safe to do so, and contact a competent person.

Who pays for the EICR in a rented commercial property?

Commercial tenants should check their lease to see who arranges and pays for testing, and ask the landlord or managing agent if it is not clear.

What should I do in an electrical emergency?

If you experience a total power cut, call 105 to report it to your local network operator. If there is a fire or a serious electric shock, call 999 immediately. Never remove covers, open a consumer unit or touch exposed wiring yourself.

Next steps

Before you hire a commercial electrical contractor, get your details in order so you can compare prices fairly.

  • Count the number of consumer units and estimate the number of circuits you have.
  • Check your commercial lease to confirm who is responsible for the electrical installation.
  • Decide whether the work must be done outside your normal opening hours.
  • Contact three registered commercial electricians to ask for written quotes.
  • Check their scheme membership on the official provider website.

Finding a competent professional protects your staff, your customers and your premises. Take the time to compare written quotes, check registrations and find an electrician near you who has the right experience for your business.

Find a top rated electrician near you

5,057 electricians across the UK, each ranked on their Google rating and the number of reviews behind it. Start with your county:

All counties and towns · The UK Top 100 electricians

Tom Fletcher
Written by
Tom Fletcher Editor

Tom researches and writes guides for Top Rated Electricians, turning prices, rules and official guidance into plain advice for homeowners. He bakes far more sourdough than the family can eat.

Looking for a trusted electrician? Browse our verified listings.

Find an Electrician